Foundation design for G+2 building as per IS 456-2000 code

Photo of author

By Shravan

Contents

Foundation design for G+2 building as per IS 456-2000 code| isolated footing | combined footing

Foundation is the concrete structure which exists below the earth. The foundation design is the method of determining the reinforcement values of footing as per the standards. In this article you can able to find how to design isolated footing and combined footing as per IS 456 2000 code standards for G+2 building structure. The isolated footing are commonly used in building structures to resists the whole building under loading condition. The combined footing is used in building structure if the center to center distance between two RCC columns is less than 3 to 2m. The complete connection between the columns is made with the help of the reinforcement under the ground in the combined footing type.

Complete building details for foundation design

The below table described points are related to the complete details of G+2 structure used in foundation design

S. No Description Property
1 Number of floors 3 (G+2)
2 Length of building 14m
3 Width of building 8m
4 Height of building with plinth 12m
5 Beam size 350mmX230mm
6 Column size 460mmX230mm
7 Slab thickness 125mm
8 Load cases Dead and Live
G+2 building design
G+2 building geometry

Isolated footing design as per IS 456-2000 code

After analysis and design is done in STAAD Pro software we have to import the supports to staad foundation design. The below figure shows the imported fixed supports for G+2 building in staad foundation.

isolated foundation
                Supports of G+2 building

Now after importing supports initially we need to create the load combinations for the foundation for that click of loads and factors on the left hand side and select the generate load combinations option. So that it will open another window which is shown in the below figure. Create the load combinations for service load and ultimate load by sing generate load combination option.

load combinations in footing design
Load combinations

After creating the load combinations now we have to create a job for isolated footing for that click on the create job option so that is will display the properties on the right hand side wind window. Provide the required data like Job name, design code as IS456 and default units in SI and support assignment to all support condition which is shown in the below figure

job set up in foundation design
Isolated footing details

Now we have to select the load combinations which are already defined as per ultimate load and service load case. And directly click in the design option so that it is display the isolated footing job option on the left hand side which contain the concrete and rebar, cover and soil, footing geometry, sliding and over turning and design enter the values as per the building design standards for that particular site. Directly click on the design option so that it will do the analysis for the isolated footing design as per IS 456-2000 code provisions. After some time the isolated footing deign results are displayed on the screen see in the below figure.

isolated results
Isolated footing design results

From this results you can select anyone of the foundation as per the requirements which is displayed in the results. The isolated footing consisting of staring page, geometry, detail and schedule drawing, GA drawing and calculation sheet. The details and drawing for sample foundation is shown in the below figure see details.

final foundation design
Final isolated footing results

As per the  design results of isolated footing for G+2 building structure it is obtained as clear cover of 50mm at the bottom, it is having the mesh of 6mm diameter bars in both X and Y direction with 70mm center to center distance between the each bar.

Combined footing design as per IS 456-2000 code

In the combined footing also initially we have to import the model to staad foundation software which is same as isolated footing and then we have to create the load combinations by using loads and factors option on the left hand side. Now we have to create the new job combined footing as per IS 456 2000code the complete process is same as per isolated footing. The combined footing input details are shown in the below figure

combined foundation design
Combined footing  details

Now we have to select the load combinations which are already defined as per ultimate load and service load case.  After that we have to create the strips in between the columns in X direction and Y direction for all the columns which is shown in the below figure.

strips
Adding strips in foundation

Now we have to click on the design option so that it is display the combined footing job option on the left hand side which contain the concrete and rebar, cover and soil, footing geometry, sliding and over turning and design enter the values as per the building design standard. Directly click on the design option so that it will do the analysis for the combined footing design as per IS 456-2000 code provisions. After some time the deign results are displayed on the screen see in the below figure.

results of foundation design
Combined footing results as per IS 456

From this results you can select anyone of the foundation as per the requirements which is displayed in the results. The combined footing is also consisting of staring page, geometry, detail and schedule drawing, GA drawing and calculation sheet. The details and drawing for sample foundation is shown in the below figure see details.

RCC
Final combined footing design results

As per the  design results of combined footing for G+2 building structure it is obtained as clear cover of 50mm at the bottom, it is having the mesh of 12mm diameter bars in both X and Y direction with 180mm and 185mm center to center distance between the each bar.

Please see the complete design details as per STAAD Pro software in my YouTube channel civil engineering by shravan see the video link below.

Conclusions of foundation design as per IS 456-2000 code

Well now the above explained concepts are related to the isolated footing and combined footing design as per IS 456 2000 code standards. For isolated footing is it obtained as 6mm diameter with 70mm center to center mesh in both X and Y direction for foundation. And for the combined footing is obtained as 12mm diameter with 180mm and 185 center to center mesh in both X and Y direction for foundation.

Please follow our previous posts here

Complete detailing of RCC building in ETABS software by using IS 456 2000 code

Which concrete mix is best site mix or ready mix? Cost comparison of site mix and ready mix concrete?

What is Transverse reinforcement? Different types of transverse reinforcement in columns?

What is Cracks in building | Types of cracks | Methods and preventions in cracks

How to calculate number of stair cases and volume of stair in building construction

Isolated footing design as per IS 456-2000 code | structural design | civil engineering

What are the load combinations used in building design as per IS 456-2000 and IS 1893-2016 code | structural design

Please watch interesting concepts in my YouTube channel Civil engineering by shravan. Please feel free to text us at contact us page for any quarries.

Thank You

Your Shravan

Have a good day.