Minimum standards are major key points in building design as per the structural engineering. Without using the minimum values it is difficult to design the structure under the specified conditions. As per the various code provisions the minimum standards will varies. But these minimum values are not to accurate. These standards are only helps in designing of ground floor or G+1 building structures only.

minimum reinforcement details, minimum standards as per thumb rule, building design,
minimum standards as per Thumb rule

The minimum standards of building structure are classified in to two categories 

  1. Materials and structural elements properties
  2. Reinforcement Details

Materials and structural elements properties in minimum standards in structural design 

Under this category the material properties like grade of the concrete, grade of the steel is considered and for elements properties the minimum stands like beam section dimensions , column section dimensions , slab section dimensions and foundation section dimensions are considered.

Beam properties

As per the Indian code provisions the minimum cross section for beam is taken as 9”X9” for ground storey building structure. By increasing in the number of floors the dimensions of beam is also varies. For the G+1 building structure design it is recommended to consider 9”X12” size dimensions.        

Column properties

For the building design under ground floor as per code provision it is recommended to take 9”X9” this will be helps till one and half storey also. For G+1 building structure the dimensions of column is taken as 9”X12” or 12”X12” depending upon the considerations.

Slab properties

The minimum dimensions of slab as per standards are taken as 4”. But for slab construction we have to use 0.5” pipe lines and extra 0.5” cover to be added to slab total of 5” slab section is considered for the slab design.  This 5” slab thickness is also helps in G+1 building design.

Foundation properties

For foundation under Ground or G+1 building minimum length and width of the foundation is used as 4’0”X4’0”.

Grade of concrete and steel

Material properties is also important in building design the minimum of M20 grade with mix ratio of 1:1.5:3 and minimum of Fe415 grade steel is considered in ground or G+1 Building design.

Reinforcement details in minimum standards in structural design 

Beam reinforcement details

For ground floor building 4numbers of bars which is 2 of 12mm diameters at top section and 2 of 10mm diameter at bottom section is enough for ground floor building. Concrete cover minimum of 40mm with M20 grade concrete mix to be adopted in building design.   

beam, beam design, reinforcement details of beam, building design,
Beam reinforcement details

Column reinforcement details

For ground floor building the column with 9”X9” size 4 bars of 12mm diameter main reinforcement and 8mm diameter stirrups with 150mm distance is taken with M20 minimum concrete grade.

For G+1 building the column with 9”X12” or 12”X12” size 6 bars of 12mm diameter main reinforcement and 8mm diameter stirrups with 150mm distance is taken with M20 minimum concrete grade.  

column design, column design as per thumb rule, building design, column,
Column reinforcement details

Slab reinforcement details

Basically slabs are classified in to two type one way slab and two way slab. For the one way slab the main reinforcement of 8mm diameter bars with 6”C/C distance is minimum, distribution reinforcement of 6mm diameter bars with 6”C/C distance is minimum for ground floor building.

For the two way slab system the main reinforcement of 8mm diameter bars with 5”C/C distance is minimum, distribution reinforcement of 8mm diameter bars with 7”C/C distance is minimum for ground floor building.

slab design, slab reinforcement, slab detailing, slab,
Slab reinforcement details

Foundation reinforcement details

 For the ground floor building with 4’0”X4’0” footing dimensions initially 6” PCC bed is laid, then 12” rectangular foundation is placed above PCC bed. The reinforcement of steel mesh with 8mm diameter at 6C/C distance in both directions is preferred.  

foundation design, minimum reinforcement details for foundation, footing design
Foundation reinforcement details

The complete concepts of Minimum standards for structural design as per Thumb rule is explained in my YouTube channel please click here to see.

Conclusions for minimum standards in structural design 

Well now the above explained concepts are related to the minimum standards for structural design as per thumb rule. Please follow my YouTube channel for more information regarding civil engineering concepts.